<?xml version="1.0" encoding="UTF-8" ?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
<channel>
                <title>ICPDAS-EUROPE GmbH/Products/Industrial Communication/Other products</title>
        <link>https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/</link>
        <description>products in category Other</description>
        <language>en</language>
        <copyright>ICPDAS-EUROPE GmbH</copyright>
        <lastBuildDate>Fri, 18 Oct 2019 13:04:58 +0200</lastBuildDate>
        <generator>ICPDAS-EUROPE GmbH</generator>
                    <managingEditor>info@icpdas-europe.com ( )</managingEditor>
                        <image>
            <url>https://www.icpdas-europe.com/out/icpdas/img/logo.png</url>
            <title>ICPDAS-EUROPE GmbH/Products/Industrial Communication/Other products</title>
            <link>https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/</link>
        </image>
        
        <atom:link href="https://www.icpdas-europe.com/en/rss/Category/Other-icpdas-5/" rel="self" type="application/rss+xml" />
                    <item>
                <title>ECAT-2093 CR 0,00 €</title>
                <link>https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/ECAT-2093-CR.html</link>
                <pubDate>Fri, 18 Oct 2019 05:30:13 +0200</pubDate>
                <description>&lt;img src=&#039;https://www.icpdas-europe.com/out/pictures/generated/product/1/390_250_80/ECAT-2093-Encoder-Counter-01_140645.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;br&gt;
The EtherCAT slave ECAT-2093 is an&amp;nbsp;incremental encoder&amp;nbsp;counter which provides three independent high-speed counter channels. It reads the pulse train generated by an incremental encoder and can be used in positioning feedback applications. Each channel has two counter inputs. The inputs can either be single-ended or differential signals. Three counting modes are supported: clockwise/counterclockwise, pulse/direction and quadrant counting mode. The hardware index latch function allows the latching of encoder position. Low pass filter functions for filtering out electrical noises are provided.</description>
                <guid isPermaLink="true">https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/ECAT-2093-CR.html</guid>
                            </item>
                    <item>
                <title>CAN-Logger100 CR 0,00 €</title>
                <link>https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/CAN-Logger100-CR.html</link>
                <pubDate>Fri, 18 Oct 2019 05:30:29 +0200</pubDate>
                <description>&lt;img src=&#039;https://www.icpdas-europe.com/out/pictures/generated/product/1/390_250_80/CAN-Logger100CR-Data-Logger-Device-01_140255.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;br&gt;
The CAN-Logger series devices (CAN-Logger100 / CAN-Logger200) are high-performance intelligent CAN bus data logger device with one/two CAN port that can help to make data collection and to process on a CAN bus network easier and quicker. The powerful CPU of the CAN-Logger devices provide the accurately time-stamp for each CAN message and supports storage media like SD or SDHC type flash for saving these CAN messages that is useful to analysis and diagnostic the CAN Bus network. In order to enhance the portability of the CAN-Logger200, this module is powered by the USB interface or M12 connectors of CAN bus interface. The CAN-Logger devices use the standard USB HID driver of the Windows system.</description>
                <guid isPermaLink="true">https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/CAN-Logger100-CR.html</guid>
                            </item>
                    <item>
                <title>MDC-714 CR 0,00 €</title>
                <link>https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/MDC-714-CR.html</link>
                <pubDate>Fri, 18 Oct 2019 05:30:31 +0200</pubDate>
                <description>&lt;img src=&#039;https://www.icpdas-europe.com/out/pictures/generated/product/1/390_250_80/MDC-714CR-Data-Concentrator-01_140202.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;br&gt;
MDC-700 series is a Modbus Data Concentrator used to access data from disparate Modbus slave devices with a contiguous Modbus address table ranged by the concentrator. Up to 240 Modbus/RTU commands can be performed to read data from Modbus slave devices via RS-232/485, and up to 8 Modbus/TCP masters are allowed to get the polled data via the Ethernet. The Modbus/TCP masters directly read/write the data in the MDC-700 instead of polling each Modbus/RTU slave device one by one. This way not only makes the data on the RS-232/485 sharable to multiple Modbus/TCP master but also shorten the time to read/write data from/to multiple Modbus/RTU slave devices.&lt;br&gt;
&lt;br&gt;
Editing the Modbus/RTU commands for accessing the Modbus RTU slaves is simple and convenient with Comma Separated Values (CSV) format. In addition, a web-based user interface is provided to configure the concentrator and remotely monitor the state of the connection of Modbus RTU slaves.&lt;br&gt;
&lt;br&gt;
Great Capability of Shared Memory&lt;br&gt;
The MDC-700 module can perform up to 240 polling definitions. And the internal shared memory has four tables to store the polled AI, AO, DI and DO data. Each table can store up to 9600 registers.&lt;br&gt;
&lt;br&gt;
Config.CSV to Ease Hard Work of Editing a lot of Definition&amp;nbsp;&amp;nbsp;&lt;br&gt;
The Modbus polling definition is defined in a Config.CSV file. Editing/checking a lot of polling definitions is a hard work and may have chance to make a mistake. A CSV format file can ease the work by using Excel. Furthermore, a built-in web server allows users import/export the Config.CSV via a simple mouse-click action.&lt;br&gt;
&lt;br&gt;
Web-based Interface for Operating and Displaying Necessary Information&amp;nbsp;&amp;nbsp;&lt;br&gt;
Users can easy to configure the concentrator and monitor the connection status through the user&#039;s regular web browser. They can also edit the polling definition Config.CSV file and import/export the Config.CSV via the web browser interface.</description>
                <guid isPermaLink="true">https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/MDC-714-CR.html</guid>
                            </item>
                    <item>
                <title>I-8120W-G CR 0,00 €</title>
                <link>https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/I-8120W-G-CR.html</link>
                <pubDate>Fri, 18 Oct 2019 05:31:14 +0200</pubDate>
                <description>&lt;img src=&#039;https://www.icpdas-europe.com/out/pictures/generated/product/1/390_250_80/I-8120W-GCR-CAN-Module-01_122548.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;br&gt;
The CAN (Controller Area Network) is a serial communication bus especially suited to interconnect smart devices to build smart systems or sub-system. It efficiently supports distributed real-time control with a very high level of security. In CAN networks, there is no addressing of subscribers or stations in the conventional sense, but instead prioritized messages are transmitted. As standalone CAN controller, I-8120W with WinPAC-8000/ViewPAC-2xWx/XPAC-8000/XPAC-8000-CE6 series MCU (main control unit) represents an economic solution. It has one CAN communication port with 5-pin screw terminal connector, and is useful for a wide range of CAN applications. Besides,I-8120W uses the new Phillips SJA1000T and transceiver 82C250, which provide both CAN 2.0A and 2.0B specific, re-transmission function, bus arbitration and error detection.&lt;br&gt;
Combining the benefits of WinPAC-8000/ViewPAC-2xWx/XPAC-8000/XPAC-8000-CE6 series MCU without increasing the CPU loading heavily, it could be a powerful multi CAN port programmable device server by driving the program in the 186 CPU ofI-8120W. It can also communicate with other kinds of communication interface, such as RS-232/RS-485/Ethernet ports to be a programmable device server. Therefore, users can design the various applications between different communication protocols.</description>
                <guid isPermaLink="true">https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/I-8120W-G-CR.html</guid>
                            </item>
                    <item>
                <title>I-87120-G 0,00 €</title>
                <link>https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/I-87120-G.html</link>
                <pubDate>Fri, 18 Oct 2019 05:31:54 +0200</pubDate>
                <description>&lt;img src=&#039;https://www.icpdas-europe.com/out/pictures/generated/product/1/390_250_80/I-87120-G-CAN-Module-01_113223.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;br&gt;
CAN (Controller Area Network) is a serial bus control protocol especially suited to constrnct intelligent industry devices networks and build smart automatic control systems. It is popularly applied in the industrial automation, building automation, vehicle, marine, and embedded control network. In order to expand the CAN functions of ICPDAS products, I-87120 module is developed for this purpose. It is a kind of module, and need to be plugged into a host unit, such as I-8000 and iP-8000 series MCU (Main Control Unit), ViewPAC-2000, WinPAC-8000, LinPAC-8000 and XPAC-8000-CE6. I-87120 give a way to connect these ICPDAS host unit with CAN network. Owing to the features of I-8000, iP-8000, ViewPAC-2000, WinPAC-8000, LinPAC-8000 and XPAC-8000-CE6, these host units can be arranged to be a CAN converter, CAN slave device and CAN master device in a CAN network. The righr-hand-side figure shows the application architecture for I-87120 modules.</description>
                <guid isPermaLink="true">https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/I-87120-G.html</guid>
                            </item>
                    <item>
                <title>HRT-370 CR 0,00 €</title>
                <link>https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/HRT-370-CR.html</link>
                <pubDate>Fri, 18 Oct 2019 05:30:15 +0200</pubDate>
                <description>&lt;img src=&#039;https://www.icpdas-europe.com/out/pictures/generated/product/1/390_250_80/HRT-370-Signal-Filter-01_140609.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;br&gt;
HRT-370 is a HART signal filter specially designed to solve the issue that analog signal gets interfered while additional HART signal adding to communication process. When connecting HRT-370 to a HART instrument, it splits the input HART signal to two output channels, one keeps the original HART signal and another filter the HART signal out to output pure analog signal. Therefore, users can make both HART and analog current data collection and processing easier and more precise by applying HRT-370.</description>
                <guid isPermaLink="true">https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/HRT-370-CR.html</guid>
                            </item>
                    <item>
                <title>ECAT-2512 CR 0,00 €</title>
                <link>https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/ECAT-2512-CR.html</link>
                <pubDate>Fri, 18 Oct 2019 05:30:25 +0200</pubDate>
                <description>&lt;img src=&#039;https://www.icpdas-europe.com/out/pictures/generated/product/1/390_250_80/ECAT-2512CR-EtherCAT-Module-01_140358.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;br&gt;
ECAT-2512 is a 1-to-2 port EtherCAT junction slaves. They are designed for realizing flexible wiring by daisy chain and branch.&lt;br&gt;
The ECAT-2512 cannot be used as a standard Ethernet switch.&lt;br&gt;
&lt;br&gt;
Benefit 1: Translate Daisy-chain to Branch Topology&lt;br&gt;
EtherCAT junction slaves can realize branch topology. They make the cabling easier than daisy-chain topology.&lt;br&gt;
&lt;br&gt;
Benefit 2: Improving the Debugging Efficiency&lt;br&gt;
If a slave device is not working or the cable is disconnected, the following slave devices on the same network all not communicate with the master controller.&lt;br&gt;
With EtherCAT junction slaves, all slave devices can be wired as separated sections. If one slave device is failed, only the slave devices on the same section will be influenced. The EtherCAT junction slave keeps the slave devices on another section communicate with the master controller. Debugging can be made separately, thus improving the debugging efficiency.</description>
                <guid isPermaLink="true">https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/ECAT-2512-CR.html</guid>
                            </item>
                    <item>
                <title>MDC-711 CR 0,00 €</title>
                <link>https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/MDC-711-CR.html</link>
                <pubDate>Fri, 18 Oct 2019 05:30:26 +0200</pubDate>
                <description>&lt;img src=&#039;https://www.icpdas-europe.com/out/pictures/generated/product/1/390_250_80/MDC-711CR-Data-Concentrator-01_140336.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;br&gt;
MDC-700 series is a Modbus Data Concentrator used to access data from disparate Modbus slave devices with a contiguous Modbus address table ranged by the concentrator. Up to 240 Modbus/RTU commands can be performed to read data from Modbus slave devices via RS-232/485, and up to 8 Modbus/TCP masters are allowed to get the polled data via the Ethernet. The Modbus/TCP masters directly read/write the data in the MDC-700 instead of polling each Modbus/RTU slave device one by one. This way not only makes the data on the RS-232/485 sharable to multiple Modbus/TCP master but also shorten the time to read/write data from/to multiple Modbus/RTU slave devices.&lt;br&gt;
&lt;br&gt;
Editing the Modbus/RTU commands for accessing the Modbus RTU slaves is simple and convenient with Comma Separated Values (CSV) format. In addition, a web-based user interface is provided to configure the concentrator and remotely monitor the state of the connection of Modbus RTU slaves.</description>
                <guid isPermaLink="true">https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/MDC-711-CR.html</guid>
                            </item>
                    <item>
                <title>USB-2020 CR 0,00 €</title>
                <link>https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/USB-2020-CR.html</link>
                <pubDate>Fri, 18 Oct 2019 05:31:12 +0200</pubDate>
                <description>&lt;img src=&#039;https://www.icpdas-europe.com/out/pictures/generated/product/1/390_250_80/USB-2020CR-Converter-01_122700.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;USB Audio Device/USB 1.1/2.0</description>
                <guid isPermaLink="true">https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/USB-2020-CR.html</guid>
                            </item>
                    <item>
                <title>ECAT-2513 CR 0,00 €</title>
                <link>https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/ECAT-2513-CR.html</link>
                <pubDate>Fri, 18 Oct 2019 05:30:09 +0200</pubDate>
                <description>&lt;img src=&#039;https://www.icpdas-europe.com/out/pictures/generated/product/1/390_250_80/ECAT-2513-EtherCAT-Module-01_140721.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;br&gt;
ECAT-2513 is a 1-to-3 port EtherCAT junction slave. It is designed for realizing flexible wiring by daisy chain and branch.&lt;br&gt;
&lt;br&gt;
The ECAT-2513 cannot be used as a standard Ethernet switch.&lt;br&gt;
&lt;br&gt;
Benefit 1: Translate Daisy-chain to Branch Topology&lt;br&gt;
EtherCAT junction slaves can realize branch topology. They make the cabling easier than daisy-chain topology.&lt;br&gt;
&lt;br&gt;
Benefit 2: Improving the Debugging Efficiency&lt;br&gt;
If a slave device is not working or the cable is disconnected, the following slave devices on the same network all not communicate with the master controller.&lt;br&gt;
&lt;br&gt;
With EtherCAT junction slaves, all slave devices can be wired as separated sections. If one slave device is failed, only the slave devices on the same section will be influenced. The EtherCAT junction slave keeps the slave devices on another section communicate with the master controller. Debugging can be made separately, thus improving the debugging efficiency.</description>
                <guid isPermaLink="true">https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/ECAT-2513-CR.html</guid>
                            </item>
                    <item>
                <title>CAN-Logger200 CR 0,00 €</title>
                <link>https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/CAN-Logger200-CR.html</link>
                <pubDate>Fri, 18 Oct 2019 05:30:29 +0200</pubDate>
                <description>&lt;img src=&#039;https://www.icpdas-europe.com/out/pictures/generated/product/1/390_250_80/CAN-Logger200CR-Data-Logger-Device-01_140256.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;br&gt;
The CAN-Logger series devices (CAN-Logger100 / CAN-Logger200) are high-performance intelligent CAN bus data logger device with one/two CAN port that can help to make data collection and to process on a CAN bus network easier and quicker. The powerful CPU of the CAN-Logger devices provide the accurately time-stamp for each CAN message and supports storage media like SD or SDHC type flash for saving these CAN messages that is useful to analysis and diagnostic the CAN Bus network. In order to enhance the portability of the CAN-Logger200, this module is powered by the USB interface or M12 connectors of CAN bus interface. The CAN-Logger devices use the standard USB HID driver of the Windows system.</description>
                <guid isPermaLink="true">https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/CAN-Logger200-CR.html</guid>
                            </item>
                    <item>
                <title>MDC-741 CR 0,00 €</title>
                <link>https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/MDC-741-CR.html</link>
                <pubDate>Fri, 18 Oct 2019 05:30:26 +0200</pubDate>
                <description>&lt;img src=&#039;https://www.icpdas-europe.com/out/pictures/generated/product/1/390_250_80/MDC-741CR-Data-Concentrator-01_140337.jpg&#039; border=0 align=&#039;left&#039; hspace=5&gt;&lt;br&gt;
MDC-700 series is a Modbus Data Concentrator used to access data from disparate Modbus slave devices with a contiguous Modbus address table ranged by the concentrator. Up to 240 Modbus/RTU commands can be performed to read data from Modbus slave devices via RS-232/485, and up to 8 Modbus/TCP masters are allowed to get the polled data via the Ethernet. The Modbus/TCP masters directly read/write the data in the MDC-700 instead of polling each Modbus/RTU slave device one by one. This way not only makes the data on the RS-232/485 sharable to multiple Modbus/TCP master but also shorten the time to read/write data from/to multiple Modbus/RTU slave devices.&lt;br&gt;
&lt;br&gt;
Editing the Modbus/RTU commands for accessing the Modbus RTU slaves is simple and convenient with Comma Separated Values (CSV) format. In addition, a web-based user interface is provided to configure the concentrator and remotely monitor the state of the connection of Modbus RTU slaves.</description>
                <guid isPermaLink="true">https://www.icpdas-europe.com/en/Products/Industrial-Communication/Other/MDC-741-CR.html</guid>
                            </item>
        </channel>
</rss>